Criticare nGenuity 8100EP:
The nGenuity™ 8100E(P) patient monitor is the perfect choice for busy departments demanding accurate, reliable performance.
Compact and lightweight, the nGenuity 8100E(P) patient monitor can monitor adults, pediatrics, and neonates in virtually every department - at bedside or in transit. The innovative user interface features simplified menus and dedicated function keys for timely set-ups. The big, bright display with large numerics can easily be seen, even from across the room.
The nGenuity 8100E(P) patient monitor mounts quickly and easily to walls, rollstands, and bedrails.
Custom Configurations
Standard: ECG, ComfortCuff™ NIBP, DOX™ SpO2, HR, Temperature, Respiration, and Nurse Call interface connection.
Optional: ST/Arrhythmia and printer
• Easy-to-read 10.4" active TFT color display - view up to 6 waveforms simultaneously.
• Easy to learn, easy to use menus, dedicated function keys, and simplified controls.
• Lightweight design and versatile mounting options - adapts readily to department and transport requirements.
ECG
Connectors: 3- or 5-lead
Leads: User-selectable; I, II, III, aVR, aVL, aVF, V (5-lead); I, II, or III (3-lead)
Gain Selection: x1/2, x1, x2, and x4
Electrosurgery Protection: Yes
Defibrillator Protection: Yes
Pacer Detection/Rejection: Yes
Non-Invasive Blood Pressure
Technique: Oscillometric measure upon inflation
Automatic Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
Measurement Range: Adult: 30 to 300mmHg; Neonate: 0 to 150 mmHg
Resolution: 1mmHg
Transducer Accuracy: ±2mmHg or ±2%, which ever is greater
STAT mode: 5 min of consecutive readings
Pulse Oximetry
Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; <50%: unspecified
Method: Dual wavelength LED
Heart (Pulse) Rate
Source: ECG (primary); IBP, Pleth; NIBP
Range: 20 to 300bpm (30-240bpm, NIBP)
Accuracy: ±1bpm or ±1% (ECG, IBP, SPO2 only)
Temperature
Channels: 1
Range, Accuracy: 68° to 94.8° F (20° to 34.9° C): ±0.5%; 95° to 107.4° F (35° to 41.9° C): ±0.2%; 107.6° to 113° F (42° to 45° C): ±0.5%
Probe: YSI-400 and YSI-700 series
Respiration
Rate: 6 to 150 breaths/min
Resolution: 1 breath/min
Accuracy: ±1% or ±1 breath/min, whichever is greater
Source: ECG-TTI
Alarms
Indication: Audible; visual
Silence: Yes; 2 min or permanent
Trend Memory
Tabular: 24 hr at 30 sec intervals
Display
Screen: 10.4" active color TFT
Resolution: 640 x 480 pixels
Waveforms: 6, maximum
Languages: English, French, German, Italian, Portuguese, Spanish, Russian, Chinese
Controls
Keys: 9; membrane-activated
Rotary Knob: Push and rotate; 24 steps/turn
System Outputs
Com Ports: RS 232-compatible; DB9 (Com 1)
Nurse Call: Contact switch; 3.5mm stereo phone jack, standard 14mm length
Defib/Sync: BNC connector
Video Port: High density D-sub 15-pin
Recorder
Type: Thermal line printer
Paper Speed: 12.5, 25, 50mm/sec
Mechanical
Weight: 14 lb; 6.4kg
Size: Base unit: 11" (H) x 13" (W) x 10.3" (D); 28cm (H) x 33cm (W) x 26.2cm (D)
Power Requirements
Voltage: 100, 120, 220, 240 VAC; 50/60 Hz
Consumption: 35 W, typical
Batteries: 1; sealed lead acid; life: 3 hr, typical; recharge time: 4.5 hr
Environmental
Operating Temperature: 59° to 95° F; 15° to 35° C
Storage Temperature: 23° to 122° F; -5° to 50° C
Operating Humidity: 15% to 90%, noncondensing
Classification
Types of Protection: Class I equipment
Degree of Protection: Type CF defib-proof
Protection Against Ingress: IPX1